PRODUCTS
DVI Cable
DVI-2Y(St)CH-4P/1P/3C-24
- (4P+1P+3C)
Construction
Element 1:4 PR×24AWG(Stranded TC/Foam PE/Individual Al-mylar Screen+ TC Drain Wire)
-
Conductors Stranded tinned copper wires, 7/0.20mm Insulation Foam Polyethylene. Thickness 0.28mm. Outer diameter 1.16+0.05mm Core Identification 1P= White/Brown; 2P=White/Red; 3P=White/Green; 4P=White/Blue Twisting The cores shall twisted together in pair, the lay between each twist shall not exceed 100 mm Individual Shield Aluminum/mylar laminated tape applied with the metallic side down in electrical contact with a 24AWG tinned copper drain wire (7 strands formation).
A mylar tape is applied over the screening tape with a minimum 25% overlap. Thickness ≥0.05mm.
-
Conductors Stranded annealed tinned copper wire, 7/0.20mm Insulation Foam polyethylene. Thickness 0.15mm. Outer diameter 0.9mm Insulation Color Yellow/Orange Twisting The cores shall twisted together in pair, the lay between each twist shall not exceed 100 mm -
Conductors Stranded annealed tinned copper wire, 7/0.20mm Insulation Foam polyethylene. Thickness 0.15mm. Outer diameter 0.9mm Insulation Color Red/Violet/White -
Overall Screen Aluminum/mylar tape. Thickness ≥0.05mm. Overlap > 25% Braid Shield Braid of tinned copper wire (0.12mm)+Wrapping tape. Coverage: 85-95%
Wrapping tape is optional.
Outer Sheath LSOH sheath,Thickness 1.0mm. Outer diameter is 10.4mm
Approx. Net Weight: 133kg/km
Sheath Color Black -
Rated Voltage 30V Max conductor resistance at 20°C ≤89.2 Ohm/Km Min insulation resistance ≥100M Ohm/m Spark test Min. AC 250V/1 second Nom. mutual capacitance at 1KHz 57 pF/m -
EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) Vertical flame propogation for a single insulated wire or cable EN 50266-2-4 + EN 50305; IEC 60332-3-24;
NF C 32-070 2.2 (C1); VDE 0472 Teil 804Vertical flame spread of vertically mounted bunched wires or cables EN 50268-2; IEC 61034-2; NF C 32-073 ;
NF C 20-902; NF F 16 101; VDE 0472 Teil 816Low Smoke Emission EN 50267-2-1; IEC 60754-1; NF C 32-074;
NF C 20-454; VDE 0472 Teil 815Halogen Free EN 50267-2-2/3; IEC 60754-2; NF C 32-074;
NF C 20-453; VDE 0472 Teil 813
Low Corrosivity (Acidity & Conductivity) EN 50305; NF X 70-100; NF F 63 808; TM1-04; BS6853 Low Toxicity NF F 63 808; BS6853; NF F 16 101 Smoke index EN45545-2 Requirement for fire behavior of materials & components R15/R16
Element 2: 1PR×24AWG(7/0.2mm) Stranded TC/Foam PE
Element 3: 3C×24AWG(7/0.2mm) Stranded TC/Foam PE
Element Assembly
Physical Properties:
Temperature rating: -25°C to +80°C
Minimum bending radius: 3 x Overall Diameter
Electrical Properties:
Fire Performance in General :
Fire Performance Relating to Rolling Stock Application
DIN 5510-2
BS 6853
NF F16 101
NF F 63 808
EN 45545-2
Corona Resistant |
Highly Flexible |
UV Resistant |
Ozone Resistant | Abrasion Retardant |
Cold- resistant |
Resistance To Soldering Heat |
Acid&Alkaline Resistant |
IRM 903 Fuel Oil Resistant |
IRM 902 Mineral Oil Resistant |
Fire Retardant NF C32-070-2.2(C2) IEC60332-3-24/EN50266-2-4 |
Flame Retardant NF C32-070-2.1(C1) IEC60332-1-2/EN50265-2-1 |
Low Toxicity NF X70-100/NF F63 808 TM1-04/BS 6853 |
Low Corrosivity IEC60754-2/EN50267-2-2/3 NF C32-074/VDE 0472-813 |
Low Smoke Emission IEC 61034-2 / EN 50268-2 NF C32-073/VDE 0472-816 |
Zero Halogen IEC 60754-1/EN 50267-2-1 NF C32-074//VDE 0472-815 |